HF-WC-601 Loop Resistance Tester

Switchgear Tester

Switchgear test instruments for circuit breaker timing, contact resistance, partial discharge and insulation testing on MV and HV switchgear and GIS.

Showing 1–24 of 41 results

Switchgear and Circuit Breaker Test Instruments

Forty-one instruments covering the test schedule of a medium- and high-voltage switchgear bay: current-path resistance, mechanical characteristics and timing, contact pressure, SF6 gas analysis, primary injection, thermal and heat-cycle testing, partial discharge and the power supplies that feed these tests.

What is in this section

  • Current path and resistance — the HF-WC-601 loop resistance tester covers 0–19999 mΩ at 0.5 % reading ±100 digits with 0.01 mΩ resolution, available with 100 A to 500 A current outputs on an AC 220 V supply, and the HF-WC-602 handheld contact resistance tester measures 5 μΩ–25 mΩ at 50 A and 5 μΩ–10 mΩ at 100 A with 0.01 μΩ minimum resolution. Also the HF-WC-603 micro ohmmeter and the HF-WC-629 switch contact resistance tester.
  • Mechanical characteristics and timing — the HF-WC-605 switchgear mechanical characteristic analyzer, the HF-WC-606 circuit breaker analyzer, the HF-WC-615 circuit breaker simulator, the HF-WC-617 DC switch ampere-second characteristic tester and the HF-WC-631 DC circuit breaker tester.
  • Contact pressure — the HF-WC-607, HF-WC-608 and HF-WC-609 disconnector, tulip and isolator contact pressure testers, together with the HF-WC-633, HF-WC-634 and HF-WC-635 contact pressure and contact force testers.
  • SF6 gas — the HF-WC-619 SF6 moisture analyzer, the HF-WC-620 gas purity analyzer, the HF-WC-621 decomposition product analyzer, the HF-WC-624 composition analyzer, the HF-WC-625 dew point meter, the HF-WC-626 gas detector, the HF-WC-627 recovery unit, the HF-WC-628 gas density relay calibrator, two leak detectors and the HF-WC-640 gas analyzer.
  • Insulation, injection and heat cycle — the HF-WC-604 programmable hipot tester, the HF-WC-622 and HF-WC-623 partial discharge testers, the HF-WC-614 primary current injection test set, the HF-WC-612 and HF-WC-613 line fitting heat cycle test sets, the HF-WC-610 and HF-WC-611 thermal relay test sets, and the HF-WC-618 vacuum interrupter tester.
  • Support and measurement — the HF-WC-616 energization test bench, the HF-WC-630 ground loop impedance tester and the HF-WC-637 switchgear test power supply.

How to choose switchgear test instruments

Work from the test item, not the instrument: breaker timing and travel need a mechanical analyzer, current-path quality needs a loop or contact resistance set at the right injection current, and SF6 work is split by what you must report — moisture, purity, decomposition products or leak rate. Confirm the voltage class, the injection current the standard requires and whether the instrument runs from mains or its own battery.

Every instrument in this section is sourced from qualified partner factories in China, verified and tested against its datasheet before shipment and delivered with its test documentation. Houfeng is a trading company and supplier, not a manufacturer.