HF-RT-216 Smart Substation Digital Relay Protection Tester

Digital Relay Protection Tester can simulate diverse power system operating conditions and fault signals. It is widely used for commissioning and routine testing of all types of protective relays in substations, power plants and industrial power distribution systems.

Send your requirements, we will quote for you within 12 hours

  • TEL: +86 13655813266
  • Whatsapp: +86 13655813266
  • zxl635973785@gmail.com

Overview

Smart Substation Digital Relay Protection Tester supports IEC 61850 communication, capable of simulating various power system faults. It tests digital protection devices and merging units, widely applied in commissioning, inspection and maintenance of smart substations and digital power grids.

Functional Requirements of HF-RT-216 Smart Substation Digital Protection Tester

Integrates optical digital testing and low analog signal testing, and allows connection to an external current and voltage power amplifier.
It supports output of 8 independent SMV messages complying with IEC60044-8 (FT3) plus 1 input channel. Synchronous/asynchronous transmission and multiple baud rates are available. Encoded pulses adopt strict 50:50 duty cycle to prevent decoding errors.
It provides 8-channel SMV message outputs conforming to IEC61850-9-2 with equally spaced sampling points, satisfying the latest State Grid standards.
It supports 24 independent digital outputs (12U+12I), which facilitates commissioning of three-winding transformer differential protection, automatic bus transfer equipment and other devices.
The tester automatically detects optical digital signals to complete auto-configuration of SMV and GOOSE information, and supports virtual terminal testing.
Built-in message waveform capture function: it receives and parses IEC61850-9-2 SMV and GOOSE messages for device self-loop testing. Optical digital signals from Merging Units (MUs) and other IEDs can be acquired, with real-time display of waveforms, amplitude, phase angle and frequency. Message recording and message analysis are also available.
Multiple groups of GOOSE messages can be transmitted and received. SMV and GOOSE optical transceivers support flexible configuration, either sharing one optical port or working independently.
The tester fully interprets ICD, CID, SCD and other protection model files. It automatically configures current/voltage channels, scaling factors, ASDU quantity, sampling rate and GOOSE parameters to simplify protection testing and boost efficiency.
It supports advanced message tests including frame loss, abnormal sampling points, frame disorder, invalid quality bits, loss of synchronization flag and wrong value injection.
Time synchronization modes include GPS, IRIG-B and IEEE1588. Commissioning for automatic bus transfer devices is supported.
It features 12 independent analog/low-signal outputs, compatible with protection devices using electronic transformer signals. When connected to third-party power amplifiers, it enables comparative testing between conventional and digital protection systems.
Equipped with 8 binary inputs, 6 binary outputs and 2 pairs of high-speed binary outputs. Together with GOOSE communication, full closed-loop protection testing can be realized.
Rich software functions support tests for line protection, busbar protection, transformer protection, generator-transformer unit protection, automatic bus transfer devices, etc.
Standard COMTRADE waveform playback is supported.
Software supports on-site upgrades and runs on all mainstream Windows operating systems. New versions can be updated directly without hardware modification.

Technical Parameters of HF-RT-216 Smart Substation Digital Protection Tester

Category Parameter Item Specification
External Interfaces Ethernet Interface 1 × 10/100Mbit
Optical Ports 12 pairs of 100Mbit, for IEC61850-9-2 SMV sampled value & GOOSE transceiving interfaces
Optical Serial Ports 9 units, for FT3 format sampled value interfaces
Built-in GPS Synchronization Interface 1 unit, SMA connector
Optical IRIG-B Interface 1 unit, ST connector
IEEE1588 Interface 1 pair, LC connector
Analog Low-Signal Voltage Source Voltage Signal Channels 12 channels, 12×(-10 ~ +10) V
Accuracy Error ≤0.05%
Resolution 215μV
Noise Amplitude <1mV
Output Frequency Range 0 ~ 1000Hz
Frequency Accuracy Error <0.001Hz
Frequency Resolution 0.001Hz
Phase Range ±360°
Phase Accuracy Error <0.1°
Phase Resolution 0.01°
Digital Output Channels Quantity 24 channels (12 voltage channels + 12 current channels)
Optical Fiber Transmission Network Transmission Network 100Base-FX (100M full-duplex optical fiber network)
Transmission Ports 12 pairs of standard LC ports, freely configurable as IEC61850-9-2 SMV transmitter or GOOSE transceiver
Transmission Medium 50/125μm or 62.5/125μm orange multimode optical fiber, wavelength 1300nm
Effective Transmission Distance >1km
Transmission Indicator Dynamic LED for transmission status
FT3 Transmission Network Transmission Network Real-time high-speed unidirectional optical fiber network, configurable speed
Transmission Ports 9 standard ST interfaces; 8 FT3 SMV message transmitting ports, 1 FT3 SMV message receiving port
Transmission Medium 62.5/125μm orange multimode optical fiber, wavelength 850nm
Effective Transmission Distance >1km
Transmission Indicator Dynamic LED for transmission status
Binary Inputs Quantity 8 pairs
Features Compatible with vacant contacts and live contacts (0 ~ 250V)
Binary Outputs Quantity 8 pairs in total
General Outputs 6 pairs of general binary outputs (vacant contacts)
High-Speed Outputs 2 pairs of high-speed binary outputs (response time <10μs)
Time Measurement Max Measuring Range 0.00001 ~ 999,999.999S
Time Accuracy ≤0.1ms
Time Synchronization Function Supported Protocols GPS, IRIG-B, IEEE1588

FAQ – Smart Substation Digital Relay Protection Tester

Q1: Which communication standards does this tester support?

A1: It supports IEC 61850-9-2 SMV, IEC 60044-8 FT3 and GOOSE protocols, fully compliant with smart substation standards.

Q2: Can it test merging units and digital protection relays?

A2: Yes. It sends SMV sampled values and GOOSE signals to verify merging units, bay-level IEDs and digital protection relays. Self-loop testing is also available.

Q3: Does the device work with both optical digital signals and analog low signals?

A3: Absolutely. It integrates optical digital testing and 12-channel analog low-signal outputs. It can connect external power amplifiers for conventional protection comparison tests.

Q4: Is automatic configuration supported for SCD/ICD/CID files?

A4: Yes. The tester can directly parse SCD, ICD and CID files to auto-set channels, scaling factors, sampling rates and GOOSE parameters, greatly saving setup time.

Q5: What time synchronization methods are available?

A5: It supports GPS, IRIG-B and IEEE1588 PTP synchronization to guarantee precise time alignment for digital substation testing.

Q6: Can I perform abnormal message interference tests?

A6: Yes. It supports frame loss, disordered frames, invalid quality bits, sync flag loss, abnormal sampling points and wrong value injection tests.

Q7: Does it support automatic bus transfer (ABT) device commissioning?

A7: Yes. With rich binary I/O and GOOSE communication, it completes closed-loop testing for auto-switchover equipment.

Q8: What waveform format can be played back?

A8: Standard COMTRADE waveform files are supported for fault recurrence and protection verification.

Q9: Can the software be upgraded on site?

A9: The software supports direct on-site upgrade and runs on mainstream Windows systems. No hardware modification is required.

Q10: What types of protection equipment can be tested?

A10: Suitable for line protection, busbar protection, transformer differential protection, generator-transformer unit protection and all digital IEDs in smart substations.

Reviews