Leave your message
- Leon Zhang sales consultant
- Email: zxl635973785@gmail.com
- Phone/WhatsApp/Wechat: +86 13655813266
HF-GT-201 Ground Resistance Tester
The ground resistance tester is widely adopted to detect earthing resistance of substations, transmission towers and buildings. With excellent anti-interference performance and high measurement accuracy, it supports convenient on-site testing to ensure grounding safety of power systems.
Send your requirements, we will quote for you within 12 hours
This Ground Resistance & Soil Resistivity Tester is elaborately developed for on-site measurement of ground resistance, soil resistivity and ground voltage. Adopting digital and microprocessor technology, it measures ground resistance via precise 4-wire, 3-wire and simple 2-wire methods. Equipped with FFT (Fast Fourier Transform) and AFC (Automatic Frequency Control) technologies, it automatically identifies interference and selects measuring frequencies to minimize interference impact and deliver highly accurate readings.
Boasting outstanding anti-interference capability and great environmental adaptability, it features excellent repeatability, ensuring long-term measurement with high precision, stability and reliability. It is widely used to test grounding parameters for power systems, telecommunications, meteorology, construction projects, lightning protection facilities and industrial electrical equipment.
The complete set consists of the main unit, data upload software, test leads, auxiliary ground rods and communication cables. The main unit is fitted with a large backlit white LCD screen and bar graph indicators for intuitive reading. It can store up to 300 groups of measurement data. With supporting software, users can conduct historical data inquiry, real-time online monitoring, dynamic display and alarm prompt; it also supports data retrieval, storage, report generation and printing functions.
Alternative names: Precision Ground Resistance Tester, 4-Wire Ground Resistance Tester, 2/3/4-Wire Ground Resistance Tester, Soil Resistivity Tester, etc.
Technical Specifications
Reference & Operating Conditions
| Influencing Factor | Reference Condition | Operating Condition | Remarks |
|---|---|---|---|
| Ambient Temperature | 23℃±1℃ | -10℃ ~ 40℃ | — |
| Ambient Humidity | 40% ~ 60% RH | <80% RH | — |
| Operating Voltage of Meter | 9V±0.1V | 9V±1.5V | — |
| Auxiliary Ground Resistance | <100Ω | <30kΩ | rC、rP |
| Interference Voltage | None | <20V | — |
| Interference Current | None | <2A | — |
| Electrode Spacing for Ground Resistance Test | a>5d | a>5d | — |
| Electrode Spacing for Soil Resistivity Test | a>20h | a>20h | — |
General Specifications
| Item | Parameter |
|---|---|
| Functions | 2/3/4-wire ground resistance measurement, soil resistivity measurement; ground voltage testing |
| Power Supply | DC 9V, 2# alkaline batteries (LR14 1.5V × 6) |
| Measuring Ranges | Ground Resistance: 0.00Ω ~ 30.00kΩ Soil Resistivity: 0.00Ω·m ~ 9000kΩ·m Ground Voltage: 0V ~ 600V |
| Measuring Mode | Precision 4-wire & 3-wire method, simple 2-wire method for ground resistance |
| Measuring Principle | Ground Resistance: Constant current variable voltage method, max. measuring current 20mA Soil Resistivity: Four-point (Wenner) method Ground Voltage: Mean value rectification (between P(S) and ES terminals) |
| Test Frequencies | 128Hz/111Hz/105Hz/94Hz (AFC automatic frequency control) |
| Test Current | >20mA (sine wave) |
| Open-circuit Test Voltage | Max. AC 40V |
| Test Voltage Waveform | Sine wave |
| Adjustable Electrode Spacing | 1m ~ 100m |
| Range Switching | Ground Resistance: Fully auto ranging 0.00Ω ~ 30.00kΩ Soil Resistivity: Fully auto ranging 0.00Ω·m ~ 9000kΩ·m |
| Backlight | Controllable white backlight, suitable for dark environments |
| Display Mode | 4-digit large LCD with white backlight |
| Measurement Indication | Flashing LED during measurement, LCD countdown & progress bar display |
| LCD Dimensions | 128mm×75mm; Viewing area: 124mm×67mm |
| Overall Instrument Size | 212mm×175mm×85mm |
| Standard Test Leads | 4 pcs: 20m red, 20m black, 10m yellow, 10m green |
| Simplified Test Leads | 2 pcs: 1.6m red, 1.6m black |
| Auxiliary Ground Rods | 4 pcs, Φ9mm × 230mm |
| Measuring Speed | Ground Voltage: approx. 3 times/second Ground Resistance & Soil Resistivity: approx. 15 seconds/time |
| Service Life | Over 5000 measurements (short-circuit test: 1 test every 30 seconds) |
| Rated Line Voltage | Measurement below AC 600V |
| Communication Interface | USB port; supporting PC monitoring, data upload, storage & printing |
| USB Cable | 1 piece, length: 1.5m |
| Data Storage Capacity | 300 groups; “FULL” symbol displayed when memory full |
| Data Hold | “HOLD” symbol for frozen readings |
| Data Recall | “READ” symbol displayed during data query |
| Over-range Indication | “OL” symbol shown when exceeding measuring range |
| Interference Detection | Automatically detect noise; “NOISE” symbol triggers when interference voltage>5V |
| Auxiliary Ground Resistance Test | Built-in function, range: 0.00kΩ~30kΩ |
| Alarm Function | Beeping alert when measured value exceeds preset threshold |
| Low Battery Prompt | Low battery icon pops up when voltage drops to ~7.5V |
| Operating Current | Standby: ~20mA (backlight off) Power-on with backlight: ~45mA (25mA without backlight) Measuring state: ~100mA (backlight off) |
| Weight | Instrument only: approx. 1330g Total weight (with package): approx. 4.5kg |
| Operating Temperature & Humidity | -10℃ ~ 40℃, RH<80% |
| Storage Temperature & Humidity | -20℃ ~ 60℃, RH<70% |
| Overload Protection | AC 280V/3s between terminals for ground resistance measurement |
| Insulation Resistance | ≥20MΩ (500V applied between circuit and housing) |
| Withstand Voltage | AC 3700V rms (between circuit and housing) |
| EMC Performance | Complies with IEC 61326 |
| Safety Standards | IEC 61010-1 (CAT III 300V, CAT IV 150V); IEC 61010-031; IEC 61557-1/-5; JJG 366-2004 |
FAQ: Ground Resistance Tester
1. What main parameters can this tester measure?
It can test ground resistance, soil resistivity and ground voltage. It supports 2-wire, 3-wire and 4-wire testing methods to meet various field grounding detection demands.
2. What anti-interference technologies does the instrument adopt?
It applies FFT and AFC automatic frequency control technologies. It automatically identifies on-site electromagnetic interference and selects optimal frequency to minimize noise for precise readings.
3. What is the measuring range of the device?
Ground resistance: 0.00Ω~30.00kΩ; Soil resistivity: 0.00Ω·m~9000kΩ·m; Ground voltage: 0~600V, covering most power and lightning protection projects.
4. Is the tester suitable for outdoor harsh working environments?
Yes. Operating temperature ranges from -10℃ to 40℃ with humidity below 80%RH, featuring strong environmental adaptability for substations, construction sites and field towers.
5. Can I store test data and export it to a computer?
It stores up to 300 groups of data. Equipped with a USB port, users can upload records to PC for checking, saving, report generation and printing via supporting software.
6. What accessories are standardly equipped together with the main unit?
Comes with 4 standard long test leads, 2 short simplified leads, 4 auxiliary ground rods, a USB communication cable and detailed operation manual.
7. Does it have automatic ranging and backlight function?
It adopts fully automatic range switching for all measurement ranges. Controllable white LCD backlight is available for easy reading in dark environments such as basements and cable trenches.
8. What alarm and prompt functions does it have?
It includes over-limit beeping alarm, low battery reminder, over-range OL display, NOISE interference prompt, HOLD data freeze and READ data query indicators.
9. What power supply does this instrument use?
Powered by six 1.5V No.2 alkaline batteries (total DC 9V). It features low power consumption and can complete more than 5000 measurement cycles continuously.
10. Which industries and scenarios is it widely used in?
Ideal for power systems, telecommunications base stations, meteorological stations, building lightning protection, industrial equipment and earthing grid safety inspection work.
11. Does the product comply with international safety standards?
It meets IEC 61010, IEC 61557 and IEC 61326 EMC standards, with reliable insulation resistance and withstand voltage performance for safe high-voltage field testing.
12. What is the total weight and dimension for portable transportation?
Main body size: 212×175×85mm; instrument weight: 1330g; total packed weight is about 4.5kg, easy to carry for outdoor field commissioning.
Reviews
There are no reviews yet.