HF-RT-203 Single phase relay test set

This portable single phase relay test set outputs adjustable AC/DC voltage and current to simulate power grid faults. It accurately tests pickup current, trip time of overcurrent, undervoltage and auxiliary relays for distribution system regular calibration.

Send your requirements, we will quote for you within 12 hours

  • TEL: +86 13655813266
  • Whatsapp: +86 13655813266
  • zxl635973785@gmail.com

Overview of Single Phase Relay Test Set

The Single Phase Relay Test Set is a compact, high-precision professional testing device designed for single-phase protective relay calibration and power system secondary circuit commissioning. It integrates stable AC/DC voltage and current output functions, supporting comprehensive testing for various common relays including measuring relays, timing relays, auxiliary relays, reclosing relays and differential relays. Adopting a high-precision 4.5-digit display and accurate millisecond timing system, it can stably measure relay pick-up value, reset value, holding value, operating time and core characteristic parameters. Lightweight and easy to operate, this test set adapts perfectly to on-site rapid maintenance, routine inspection and laboratory performance verification of power distribution systems, fully meeting standard technical requirements for relay protection testing.

Product Features

  1. Measuring Relays: Capable of testing the pick-up value, reset value and reset coefficient of current relays and voltage relays.
  2. Timing Relays: Available to measure pick-up value, reset value and operating time.
  3. Auxiliary Relays: Test pick-up value, reset value, holding value and operating time for all types of auxiliary relays with operating coils and holding coils.
  4. Reclosing Relays: Support capacitor charging test, charging duration, reclosing time and testing of internal intermediate components.
  5. Differential Relays: Perform DC excitation test, braking characteristic test and volt-ampere characteristic test.
  6. All other uncommon types of protective relays.

Technical Parameters

Category Item Specifications
Operating Conditions Input Power Supply AC 220V ±10%, 50Hz
Ambient Temperature -10℃ ~ 40℃
Ambient Humidity ≤85%
Atmospheric Pressure 86 ~ 106 kPa
Output Power Sources AC Voltage Output 0 ~ 220V, 3A
AC Current Output 0 ~ 100A / 7.5V
0 ~ 20A / 25V
0 ~ 5A / 5V
DC Voltage Output 0 ~ 220V, 3A
DC Current Output 0 ~ 20A / 25V
Fixed DC Output Voltage DC24V, DC48V, DC110V, DC220V
Performance Specifications Current & Voltage Meter 4½ digit digital display
Digital Millisecond Chronometer Measuring range: 0 ~ 99.9999 s

Packing List – Single Phase Relay Test Set

No.
Item Description
Qty
Unit
Remarks
1
Single Phase Relay Test Set Main Unit
1
Set
Core equipment
2
AC220V Power Cord
1
Pcs
Mains power connection
3
Voltage & Current Test Lead Set
1
Set
For relay testing connection
4
Switch Signal Test Cables
1
Set
Trip & signal detection
5
English Operation Manual
1
Copy
Official operation guide
6
Factory Calibration Certificate
1
Copy
Test accuracy certification
7
Quality Inspection Report
1
Copy
Pre-delivery inspection
8
Spare Fuses
1
Pack
Consumable spare parts
9
Export Wooden Case / Carton
1
Pcs
Shockproof packaging

FAQ: Single Phase Relay Test Set

Q1: What is a Single Phase Relay Test Set?

A1: It is portable secondary injection test equipment designed to calibrate single-phase protection relays. It outputs adjustable AC/DC voltage & current to simulate grid faults, verifying pickup value, trip time, reset characteristic of overcurrent, undervoltage, auxiliary relays widely used in distribution power systems.

Q2: What types of relays can this device test?

A2: Overcurrent relays (ANSI 51), undervoltage/overvoltage relays, thermal overload relays, auxiliary control relays, earth fault relays, electromagnetic relays, and small motor protection relays for 0.4kV~10kV distribution networks.

Q3: Where is the single-phase relay tester mainly applied?

A3: Power distribution stations, industrial plant power rooms, railway power supply systems, electrical maintenance companies, electrical engineering contractors, and small hydropower stations for daily relay inspection & periodic calibration.

Q4: What is the core advantage compared with 3-phase relay test sets?

A4: Lighter weight, compact size, lower cost, easy to carry for on-site field tests. Perfect for routine single-element relay checking; multiple units can be cascaded temporarily for simple 3-phase relay testing if needed.

Q5: What is the standard output range of current and voltage?

  • AC Current: 0~50A continuous adjustable; DC Current: 0~10A
  • AC Voltage: 0~250V; DC Voltage: 0~120V
  • Frequency: 50Hz/60Hz switchable
  • Measurement accuracy: ±0.5% FS

Q6: Does it support timing test for relay operating time?

A6: Yes. Built-in high-precision timer (range 0~999.99s, resolution 1ms), automatically records relay pickup & trip reset time during testing.

Q7: Can it output harmonic signals?

A7: Standard version supports 2nd~5th harmonic superimposition, meeting thermal relay & overload protection testing requirements.

Q8: What working environment can the tester adapt to?

A8: Operating temperature: -10℃ ~ +40℃; relative humidity ≤80% (non-condensing); suitable for indoor lab and outdoor field maintenance.

Q9: How to perform an overcurrent relay pickup test step by step?

  1. Connect tester current output terminals to relay current input loop correctly
  2. Set initial low current value, slowly ramp up current
  3. Stop output once relay trips, record the pickup current value
  4. Test 3 times repeatedly to confirm data consistency.

Q10: Why does the tester show overload alarm during current output?

A10: 3 common reasons:
  1. Current loop open circuit or loose wiring terminals
  2. Output current exceeds the tester maximum continuous load capacity
  3. Short-circuit occurs on voltage output loop. Cut off power immediately, check all wiring before restarting.

Q11: The tester cannot capture relay trip action signal, how to fix?

  • Check trip contact wiring (NO/NC contact selection error is the most common cause)
  • Verify switch channel polarity setting on the tester
  • Confirm the relay has enough auxiliary power supply to actuate contacts.

Q12: Can the device store test reports and export data?

A12: Yes. Built-in memory saves test records; equipped with USB interface to export data to PC for report archiving and printing.

Q13: No display after powering on the tester?

A13: Check input AC220V power supply; inspect internal power fuse blown; contact our after-sales team for hardware repair if fuse replacement still fails.

Q14: Output value deviates greatly from the set value?

  1. Re-calibrate the instrument regularly
  2. Avoid long-time full-load continuous output
  3. Keep the tester away from strong electromagnetic interference environment.

Q15: PC software fails to communicate with the tester?

A15: Confirm USB/serial cable intact; match baud rate & communication protocol; reinstall supporting test software on the computer.

Reviews

There are no reviews yet.

Be the first to review “HF-RT-203 Single phase relay test set”

Your email address will not be published. Required fields are marked *